Features
● A wide range of norminal specs are available. Accurate adjustment can be done according to application.
● Favourable power / weight ratio
● Optimum efficiency
● High starting efficiency
● SAE flange or a threaded working port.
● Integrated pressure relief valve can be chosen
● Optional pre-installed additional valves: Motion control valve (BVD/BVE), flushing and boost pressure relief valve
● Bent axis design



Parameters
High-pressure Fixed Displacement Piston Motor TFA2FM 6X Series
| Item | Symbol | Unit | 5 | 10 | 12 | 16 | 23 | 28 | 32 | 45 | 56 | 63 | 80 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Size | 5 | 10 | 12 | 16 | 23 | 28 | 32 | 45 | 56 | 63 | 80 | ||
| Displacement (per revolution) | Vg | cm³ | 4.93 | 10.3 | 12 | 16 | 22.9 | 28.1 | 32 | 45 | 56 | 63 | 80 |
| Nominal pressure | Pnom | bar | 315 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 |
| Maximum pressure | Pmax | bar | 350 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 |
| Maximum rotation speed | nnom¹) | rpm | 10000 | 8000 | 8000 | 8000 | 6300 | 6300 | 6300 | 5600 | 5000 | 5000 | 4500 |
| Maximum rotation speed | nmax²) | rpm | 11000 | 8800 | 8800 | 8800 | 6900 | 6900 | 6900 | 6200 | 5500 | 5500 | 5000 |
| Input flow at nnom | qV | l/min | 49 | 82 | 96 | 128 | 144 | 177 | 202 | 255 | 281 | 315 | 362 |
| Torque at pnom | M | Nm | 24.7 | 66 | 76 | 102 | 146 | 179 | 204 | 290 | 357 | 401 | 512 |
| Torsional Stiffness | c | kNm/rad | 0.63 | 0.92 | 1.25 | 1.59 | 2.56 | 2.93 | 3.12 | 4.18 | 5.94 | 6.25 | 8.73 |
| Moment of inertia of about drive axis | JTW | kg·m² | 0.00006 | 0.0004 | 0.0004 | 0.0004 | 0.0012 | 0.0012 | 0.0012 | 0.0024 | 0.0042 | 0.0042 | 0.0072 |
| Maximum angular Acceleration | α | rad/s² | 5000 | 5000 | 5000 | 5000 | 6500 | 6500 | 6500 | 14600 | 7500 | 7500 | 6000 |
| Case volume | V | l | 0.17 | 0.17 | 0.17 | 0.2 | 0.2 | 0.2 | 0.2 | 0.33 | 0.45 | 0.45 | 0.55 |
| Weight (approximate) | m | kg | 2.5 | 5.4 | 5.4 | 5.4 | 9.5 | 9.5 | 9.5 | 13.5 | 18 | 18 | 23 |
| Item | Symbol | Unit | 90 | 107 | 125 | 160 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Size | 90 | 107 | 125 | 160 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 | ||
| Displacement (per revolution) | Vg | cm³ | 90 | 106.7 | 125 | 160.4 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 |
| Nominal pressure | Pnom | bar | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 350 | 350 | 350 | 350 |
| Maximum pressure | Pmax | bar | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 400 | 400 | 400 | 400 |
| Maximum rotation speed | nnom¹) | rpm | 4500 | 4500 | 4000 | 3600 | 3600 | 2750 | 2700 | 2240 | 2000 | 1600 | 1800 |
| Maximum rotation speed | nmax²) | rpm | 5000 | 4400 | 4400 | 4000 | 4000 | 3000 | |||||
| Input flow at nnom | qV | l/min | 405 | 427 | 500 | 577 | 648 | 550 | 675 | 795 | 1000 | 1136 | 1600 |
| Torque at pnom | M | Nm | 573 | 679 | 796 | 1021 | 1146 | 1273 | 1393 | 1978 | 2785 | 3955 | 5570 |
| Torsional Stiffness | c | kNm/rad | 9.14 | 11.2 | 11.9 | 17.4 | 18.2 | 57.3 | 73.1 | 96.1 | 144 | 270 | 324 |
| Moment of inertia of about drive axis | JTW | kg·m² | 0.0072 | 0.0116 | 0.0116 | 0.022 | 0.022 | 0.0353 | 0.061 | 0.102 | 0.178 | 0.55 | 0.55 |
| Maximum angular Acceleration | α | rad/s² | 6000 | 4500 | 4500 | 3500 | 3500 | 11000 | 10000 | 8300 | 5500 | 4300 | 4500 |
| Case volume | V | l | 0.55 | 0.8 | 0.8 | 1.1 | 1.1 | 2.7 | 2.5 | 3.5 | 4.2 | 8 | 8 |
| Weight (approximate) | m | kg | 23 | 32 | 32 | 45 | 45 | 66 | 73 | 110 | 155 | 325 | 336 |
1) These values are valid under the following conditions:
- Within the optimal viscosity range νopt=36 to 16 mm²/s
- Using mineral oil-based hydraulic fluid
2) Maximum intermittent speed: for overspeed during unloading and maintenance, t<5 s and Δp<150 bar
3) Input flow limitation via counterbalance valve
4) Torque without radial forces / with radial forces, see table "Permitted radial and axial forces on the drive shaft"Note
The values in the table are theoretical values, and do not take efficiency and tolerances into account. These values have
been rounded.
Exceeding the permitted maximum values or falling below the permitted minimum values may result in loss of function,
reduced service life, or complete destruction of the axial piston unit. For other permitted limit values, such as speed changes,
angular acceleration as a negative function of frequency, and the permitted angular acceleration during start-up (less than the maximum angular acceleration), please refer to data sheet 90261.
Exhibitions
We make full use of international exhibitions to establish long-term OEM partnerships with worldwide clients. Our engineers discuss project specifications and customized hydraulic manifold solutions on site. From product R&D to bulk shipment, Taifeng delivers one-stop hydraulic system service and reliable worldwide delivery.

FAQ
Q1:Can you provide a sample before a big order?
A:Yes, we can.
Q2:How long has your company run in Hydraulic Fields?
A:Over 22 years
Q3:Which payment terms do you accept?
A:L/C, T/T, DDU.
Q4: What is your delivery time?
A:It depends on whether there are stocks. If there're stocks, we can ship it within one week. It will take about 30days for new production.
Q5: Is your company accept customization?
A: Yes, we accept customized products.